YT-QS-A LOAD CELL

CAPACITY RANGES:

1015202530t

         The construction with steel ball and cap has many advantages in self-returning place. High precision and reliability super stability. It can work properly in severe circumstances, suitable for truck scale, and other special scales for weighing and force measurement.

 

Wiring Color Code

+Input Red

-Input Black

+Output Green

-Output White

 

    SPECIFICATIONS 

Sensitivity:

2 ± 0.2mV/V

Tolerance on sensitivity:

± 0.05%~±0.1

Hysteresis error:

± 0.03%

Non-linearity:

± 0.02%

Creep over30min:

± 0.03%F.S

Input Resistance:

770±10Ω

0utput Resistance:

700±5Ω

Insulation Resistance:

5000mΩ

Temperature compensation range:

−10~+40

Safe temperature range:

−20~+60

Safe load limit:

150%F.S

Breaking load limit:

300%F.S

 

 

 

     CAPACITY (t)

A

B

C

D

E

F

G

H

I

J

1015

168

240

80

4ר18

100

135

Ø50.8

Ø98

25

Ø30

2030

203

240

80

4ר18

100

135

Ø76.2

Ø98

25

Ø30

Company name:Yuntong Percision Measuring Equipment Manufacture Co.,Ltd